-
loading
Ads with pictures

Cell solar


Top sales list cell solar

Chennai (Tamil Nadu)
350 watts, 12 volt 275 watts, 24 volt 350 watts, 36 volt Cell 156 mm ×156 mm Glass 3.2 mm Aluminum frame 40 millimeters Withstand high wind Wind capacity 200 kmpl 8mm elliptical diameter for bold Bold and nut clamp holes 8*16mm (elliptical diameter) Eva Optical transmittance % ASTM E424 >91 Transmittance in Ultraviolet range 290 to 380 nm % ASTM E424 >80 UV cut off wavelength nm ASTM E424 - 360 Refractive index - ISO 489 Fluoride combination white sheet used in the last layer of solar panels. It withstands high uv resistance for 25 years. Output generation is expected more than 30 plus years. Aerodynamic design at edges of frame is considered. Five bus bar Five bus bar soldering is made to minimize Power loss High Electrical conductivity bus bar used in manufacturing. Since copper content is high, resistivity is minimised. Six square cable attached with mc4 connector. Uv resistance cable. Water resistance rating : ip65 Can support both sunny days and rainy days Solar roof Minimize room temperature, since roof is not directly heated by morning radiation. Use of air conditioners minimized. Adds esthetic perspective of place. Adds value to product. House constructed with solar have good value. Manufactured to the convenience Double glass solar panels - for esthetic look, terrace garden, allows more sun light than normal panel. Bifacial solar panel - power production is made both side. Roof with white cooling tiles can prefer bifacial panels. High wattage electricity product in small area. Flexible panels - used in camping, cantilever projects. Less weight project. Electrical vehicles prefer this product Specific projects with their own specifications also designed. Design without inverter Since inverter consumes more electricity. Nowadays, inverterless design is preferred. 350 watts, 84 volt solar panels for water pump is manufactured. Vfd generally need more than 440 volt. So, panels with eighty four volt is designed. Thus, four hundred and forty volt achieved by five panels. Which rather can only be achieved by ten number of panels. Cell efficiency 20% Generates electricity even in low sunlight. High efficiency cell ensures power production even by early morning and late evening. Power generation is recorded even on cloudy situations. Panel oriented 90% to sun Chennai thirteen degree north Madurai eleven degree north One pallet - twenty six solar panels Panel dimension - 2000×990×40 mm 6.6 feet × 3.3 feet One container 22 feet - 20 pallets Area 1 kw - approximately hundred square feet Structure - design which allows air is fabricated. Structure can be made in stainless steel, m.s., galvanized iron based on site requirement. 12 feet structure is designed for requirement. Which is used as roof top shade area. It makes roof available for other uses. This design is convenient for replacing from one place to another. When shifting house also, solar panels can be shifted from one place and fixed in other place easily. Kindly contact/WhatsApp for more details
See product
India
Heavy DUTY}  Solar Power Panel Dual USB  External Mobile Battery Charger mAh Power Bank. For all Mobile Phones, Tablets, MP3 / Mp4 players, PDA, PSP, etc Item Description: Solar Panel:1.5W Cell type: Li-polymer battery  Capacity: mAh  Input:DC 5.0V -1 A  Output: 5.0 V/2.+1A    Important Tip: First before using this product. Ensure For this product is Full power. Features: Features: Brand new and high quality. Stylish, portable, user-friendly and durable for on the go use. High capacity, solar powered, environmentally-friendly. Emergency charger for cell phone and other compatible devices. Wide comparable long cycle life, rapid charge environmental friendliness @ economic efficiency No loss standby used the time longer super protection function, core intelligent function, the over charge protection, discharge protection, leakage protection shutdown state rechargeable can show power High conversion efficiency, the power rating power conversion is as high as 90% above far higher then similar products Have intellectual dormancy function, when the equipment used will automatically adjust current output, really a play a plug and play Package Included: 1 x Dual USB Solar Power Charger 1 x USB Cable 4 x Charger Adapter  Applications: iPhone/iPad/iPod, Mobile phone, MP3/MP4, PDA, PSP, digital camera etc.   The Solar Charge is a compact and lightweight solar charger designed for people on the move. Solar Charge is designed  as a backup power supply to power virtually any portable devices like Cell Phones, Smart Phones, Cameras, MP4/MP3 Players GPS and more. Just place it under day sun light and after the internal battery is fully charged you can supply power to any device with built
₹ 1.799
See product
India
If you are looking for a solar hybrid system, your search is finish here. We are the well-known manufacturers, supplier and exporter of Solar Hybrid System. We provide best Solar Hybrid System at low cost with one year warranty. A hybrid solar system with high temperature stage is described. The system contains a radiation concentrator, a photovoltaic solar cell and a heat engine or thermoelectric generator to produce electricity. For more detail, please call us at - or visit our website http://www.alfredkim.com
See product
Lalbahadur Nagar (Andhra Pradesh)
Shital Industries is a complete turnkey solution provider in the Solar Photovoltaic sector. Shital Industries is More Channel Partner (New Entrepreneurs Category) under Grid connected Solar Photovoltaic System. Apart from that Shital Industries is in one of the few suppliers who are registered under Nabard Solar Water Pumping Programmers and Solar Home Light System of More for providing the subsidy.
See product
India
Item Description ---------------------------------------------------      Solar Panel of 6Volts 5Watts     Dimensions: 27.8 cm x 18.6 cm     Glass Thickness: 3.2 mm Specifications -------------------------     Rated Max Power (Pmax): 5W     Current at Pmax (Imp): 0.58A     Voltage at Pmax (Vmp): 8.7V     Short-Circuit Current (Isc): 0.62A     Open-circuit Voltage (Voc): V     Normal Operating Cell Temp (Tnoct): -40C~50°C Feature -----------------      High-quality cells     Wide power-range     Tempered glass for rugged protection.     ISO certified manufacturing facility     IEC certification by Euro Test and TUV     Competitive price-performance ratio
₹ 675
See product
India
It is important to verify the wattage of any panel based on datasheet before considering a purchase. Here are the Simple Tests to confirm Wattage for 12v applications with PWM Solar charge controller before you order;   Test1:    Number of Cells, If it is 36 –  OK Test2:    Ask Vmp. If it is a fixed value between 17v to 18v -  OK  (Because  e ach cell is supposed to be approximately 0.5V) Test3:    Ask Imp.  If it is fixed value between   to A for 20Watt Panel. - OK Test4:    Multiply Vmp with Imp. If it comes to 20W  –  OK (i.e. 17V X Amp = 20 Watt or 18V X Amp = 20Watt) 20 W panel is 36 cell, Vmp of 17V-18V, Imp of A-Amp and 17V X Amp = 20 Watt, and 18V x Amp = 20 Watt Solar Charger Controller 12V/6A PWM Solar Charge/Charger Controller with Mobile Charger 2yr warranty Series solar charge controllers are used
₹ 1.800
See product
Lalbahadur Nagar (Andhra Pradesh)
Waaree 375 Watt Monocrystalline Panel is one of the highest electricity-producing solar panel by Waaree India. This solar panel is ideal for use in large projects like solar rooftop system for factories, hotels, schools, hospitals, etc with low space on the roof and high energy requirement. This solar panel is potential induced degradation(PID) resistant. PID impacts the ions of solar cell and results in the degradation of the output of that cell, thus it being PID resistant ensures you longer life of the solar cells. It also assures that the performance does not degrade with time. SSSCART are dealers of Waaree India and also provide customized rooftop solar systems to fit your needs at the lowest price in India.
See product
India
It is important to verify the wattage of any panel based on datasheet before considering a purchase. Here are the Simple Tests to confirm Wattage for 12v applications with PWM Solar charge controller before you order;   Test1:    Number of Cells, If it is 36 –  OK Test2:    Ask Vmp. If it is a fixed value between 17v to 18v -  OK  (Because  e ach cell is supposed to be approximately 0.5V) Test3:    Ask Imp.  If it is fixed value between   to A for 20Watt Panel. - OK Test4:    Multiply Vmp with Imp. If it comes to 20W  –  OK (i.e. 17V X Amp = 20 Watt or 18V X Amp = 20Watt) 20 W panel is 36 cell, Vmp of 17V-18V, Imp of A-Amp and 17V X Amp = 20 Watt, and 18V x Amp = 20 Watt Please note that before we ship the product to our customers, we inspect and test the product carefully to make sure it’s
₹ 1.600
See product
Delhi (Delhi)
Visit rajivihaan shop on http://stores..in/rajivihaan for other Solar, DC, or AC-DC Energy Efficient Products and Solutions   It is important to verify the wattage of any panel based on datasheet before considering a purchase. Here are the Simple Tests to confirm Wattage for 12v applications with PWM Solar charge controller before you order;   Test1:    Number of Cells, If it is 36 –  OK   Test2:    Ask Vmp. If it is a fixed value between 17v to 18v -  OK  (Because  e ach cell is supposed to be approximately 0.5V)   Test3:    Ask Imp.  If it is fixed value between 5.55A to 5.88A for 100Watt Panel. - OK   Test4:    Multiply Vmp with Imp. If it comes to 100W  –  OK (i.e. 17V X 5.88Amp = 100 Watt or 18V X 5.55Amp = 100Watt)   Test5:    Please insist for the datasheet, and verify these figures
₹ 607.500
See product
India
Visit Rajivihaan shop on http://stores..in/rajivihaan for other Solar, DC, or AC-DC Energy Efficient Products and Solutions. Please click here for rajivihaan shop http://stores..in/rajivihaan   Please contact us at    or visit our website for more details:  www.gaonsegaon.com It is important to verify the wattage of any panel based on datasheet before considering a purchase. Here are the Simple Tests to confirm Wattage for 12v applications with PWM Solar charge controller before you order; Test1:   Number of Cells, If it is 36 –  OK Test2:   Ask Vmp. If it is a fixed value between 17v to 18v - OK (Because e ach cell is supposed to be     approximately 0.5V) Test3:   Ask Imp. If it is fixed value between   to A for 20Watt Panel. - OK Test4:   Multiply Vmp with Imp. If it comes to 20W – OK (i.e. 17V X Amp = 20 Watt or 18V X Amp = 20Watt) Test5:   Please insist for the datasheet, and verify these figures
₹ 163.100
See product
India
Visit rajivihaan shop on http://stores..in/rajivihaan for other Solar, DC, or AC-DC Energy Efficient Products and Solutions   Please contact us at    or visit our website for more details:  www.gaonsegaon.com It is important to verify the wattage of any panel based on datasheet before considering a purchase. Here are the Simple Tests to confirm Wattage for 12v applications with PWM Solar charge controller before you order;   Test1:    Number of Cells, If it is 36 –  OK   Test2:    Ask Vmp. If it is a fixed value between 17v to 18v -  OK  (Because  e ach cell is supposed to be approximately 0.5V)   Test3:    Ask Imp.  If it is fixed value between 6.94A to 7.35A for 125Watt Panel. - OK   Test4:    Multiply Vmp with Imp. If it comes to 125W  –  OK (i.e. 17V X 7.35Amp = 125 Watt or 18V X 6.94Amp = 125Watt)   Test5:    Please insist for the datasheet, and verify these figures
₹ 759.300
See product
India
Visit rajivihaan shop on http://stores..in/rajivihaan for other Solar, DC, or AC-DC Energy Efficient Products and Solutions.   Please contact us at    or visit our website for more details:  www.gaonsegaon.com It is important to verify the wattage of any panel based on datasheet before considering a purchase. Here are the Simple Tests to confirm Wattage for 12v applications with PWM Solar charge controller before you order;   Test1:    Number of Cells, If it is 36 –  OK   Test2:    Ask Vmp. If it is a fixed value between 17v to 18v -  OK  (Because  e ach cell is supposed to be approximately 0.5V)   Test3:    Ask Imp.  If it is fixed value between 3.33 A to 3.53A for 60Watt Panel. - OK   Test4:    Multiply Vmp with Imp. If it comes to 60W  –  OK (i.e. 17V X 3.53Amp = 60 Watt or 18V X 3.33Amp = 60Watt)   Test5:    Please insist for the datasheet, and verify these figures
₹ 373.300
See product
India
Visit rajivihaan shop on http://stores..in/rajivihaan for other Solar, Dc, or AC-DC Energy Efficient Products and Solutions Please contact us at    or visit our website for more details:  www.gaonsegaon.com It is important to verify the wattage of any panel based on datasheet before considering a purchase. Here are the Simple Tests to confirm Wattage for 12v applications with PWM Solar charge controller before you order;   Test1:   Number of Cells, If it is 36 –  OK   Test2:   Ask Vmp. If it is a fixed value between 17v to 18v - OK (Because e ach cell is supposed to be     approximately 0.5V)   Test3:   Ask Imp. If it is fixed value between 2.22A to 2.35A for 40Watt Panel. - OK   Test4:   Multiply Vmp with Imp. If it comes to 40W – OK (i.e. 17V X 2.35Amp = 40 Watt or 18V X 2.22Amp = 40Watt)   Test5:   Please insist for the datasheet, and verify these figures
₹ 248.900
See product
India
Visit rajivihaan shop on http://stores..in/rajivihaan for other Solar, DC, or AC-DC Energy Efficient Products and Solutions   Please contact us at    or visit our website for more details:  www.gaonsegaon.com It is important to verify the wattage of any panel based on datasheet before considering a purchase. Here are the Simple Tests to confirm Wattage for 12v applications with PWM Solar charge controller before you order;   Test1:    Number of Cells, If it is 36 –  OK   Test2:    Ask Vmp. If it is a fixed value between 17v to 18v -  OK  (Because  e ach cell is supposed to be approximately 0.5V)   Test3:    Ask Imp.  If it is fixed value between 4.11A to 4.35A for 74Watt Panel. - OK   Test4:    Multiply Vmp with Imp. If it comes to 74W  –  OK (i.e. 17V X 4.35Amp = 74 Watt or 18V X 4.11Amp = 74Watt)   Test5:    Please insist for the datasheet, and verify these figures
₹ 460.500
See product
India
Visit our shop on http://stores..in/rajivihaan for other Solar DC or AC-DC Energy Efficient Products and Solutions Please contact us at    or visit our website for more details:  www.gaonsegaon.com It is important to verify the wattage of any panel based on datasheet before considering a purchase. Here are the Simple Tests to confirm Wattage for 12v applications with PWM Solar charge controller before you order;   Test1:    Number of Cells, If it is 36 –  OK   Test2:    Ask Vmp. If it is a fixed value between 17v to 18v -  OK  (Because  e ach cell is supposed to be approximately 0.5V)   Test3:    Ask Imp.  If it is fixed value between 8.33A to 8.82A for 150Watt Panel. - OK   Test4:    Multiply Vmp with Imp. If it comes to 150W  –  OK (i.e. 17V X 8.82Amp = 150 Watt or 18V X 8.33Amp = 150Watt)   Test5:    Please insist for the datasheet, and verify these figures
₹ 888.900
See product
India
Visit rajivihaan shop on http://stores..in/rajivihaan for other Solar, DC, or AC-DC Energy Efficient Products and Solutions   Please visit our website for more details: www.gaonsegaon.com    or contact us at   It is important to verify the wattage of any panel based on datasheet before considering a purchase. Here are the Simple Tests to confirm Wattage for 12v applications with PWM Solar charge controller before you order;   Test1:    Number of Cells, If it is 36 –  OK   Test2:    Ask Vmp. If it is a fixed value between 17v to 18v -  OK  (Because  e ach cell is supposed to be approximately 0.5V)   Test3:    Ask Imp.  If it is fixed value between 5.55A to 5.88A for 100Watt Panel. - OK   Test4:    Multiply Vmp with Imp. If it comes to 100W  –  OK (i.e. 17V X 5.88Amp = 100 Watt or 18V X 5.55Amp = 100Watt)   Test5:    Please insist for the datasheet, and verify these figures
₹ 607.500
See product
India
Please visit rajivihaan shop on http://stores..in/rajivihaan  for other Solar, DC, or AC-DC Energy Efficient Products and Solutions, http://stores..in/rajivihaan Please contact us at  , or visit our website for more details: www.gaonsegaon.com    It is important to verify the wattage of any panel based on datasheet before considering a purchase. Here are the Simple Tests to confirm Wattage for 12v applications with PWM Solar charge controller before you order;   Test1:   Number of Cells, If it is 36 –  OK   Test2:   Ask Vmp. If it is a fixed value between 17v to 18v - OK (Because e ach cell is supposed to be     approximately 0.5V)   Test3:   Ask Imp. If it is fixed value between   to A for 20Watt Panel. - OK   Test4:   Multiply Vmp with Imp. If it comes to 10W – OK (i.e. 17V X Amp = 10 Watt or 18V X Amp = 10Watt)   Test5:   Please insist for the datasheet, and verify these figures
₹ 85.500
See product
India
Visit rajivihaan shop on http://stores..in/rajivihaan for other Solar, DC, or AC-DC Energy Efficient Products and Solutions   Please contact us at    or visit our website for more details:  www.gaonsegaon.com/ecommerce It is important to verify the wattage of any panel based on datasheet before considering a purchase. Here are the Simple Tests to confirm Wattage for 12v applications with PWM Solar charge controller before you order;   Test1:    Number of Cells, If it is 36 –  OK   Test2:    Ask Vmp. If it is a fixed value between 17v to 18v -  OK  (Because  e ach cell is supposed to be approximately 0.5V)   Test3:    Ask Imp.  If it is fixed value between 4.11A to 4.35A for 74Watt Panel. - OK   Test4:    Multiply Vmp with Imp. If it comes to 74W  –  OK (i.e. 17V X 4.35Amp = 74 Watt or 18V X 4.11Amp = 74Watt)   Test5:    Please insist for the datasheet, and verify these figures
₹ 4.535
See product
India
Visit rajivihaan shop on http://stores..in/rajivihaan for other Solar, DC, or AC-DC Energy Efficient Products and Solutions   Please contact us at    or visit our website for more details:  www.gaonsegaon.com/ecommerce It is important to verify the wattage of any panel based on datasheet before considering a purchase. Here are the Simple Tests to confirm Wattage for 12v applications with PWM Solar charge controller before you order;   Test1:    Number of Cells, If it is 36 –  OK   Test2:    Ask Vmp. If it is a fixed value between 17v to 18v -  OK  (Because  e ach cell is supposed to be approximately 0.5V)   Test3:    Ask Imp.  If it is fixed value between 6.94A to 7.35A for 125Watt Panel. - OK   Test4:    Multiply Vmp with Imp. If it comes to 125W  –  OK (i.e. 17V X 7.35Amp = 125 Watt or 18V X 6.94Amp = 125Watt)   Test5:    Please insist for the datasheet, and verify these figures
₹ 7.170
See product
India
Visit our shop on http://stores..in/rajivihaan for other Solar DC or AC-DC Energy Efficient Products and Solutions Please contact us at    or visit our website for more details:  www.gaonsegaon.com/ecommerce It is important to verify the wattage of any panel based on datasheet before considering a purchase. Here are the Simple Tests to confirm Wattage for 12v applications with PWM Solar charge controller before you order;   Test1:    Number of Cells, If it is 36 –  OK   Test2:    Ask Vmp. If it is a fixed value between 17v to 18v -  OK  (Because  e ach cell is supposed to be approximately 0.5V)   Test3:    Ask Imp.  If it is fixed value between 8.33A to 8.82A for 150Watt Panel. - OK   Test4:    Multiply Vmp with Imp. If it comes to 150W  –  OK (i.e. 17V X 8.82Amp = 150 Watt or 18V X 8.33Amp = 150Watt)   Test5:    Please insist for the datasheet, and verify these figures
₹ 8.800
See product
India
Please visit rajivihaan shop on http://stores..in/rajivihaan  for other Solar, DC, or AC-DC Energy Efficient Products and Solutions, http://stores..in/rajivihaan Please contact us at    , or visit our website for more details: www.gaonsegaon.com/ecommerce    It is important to verify the wattage of any panel based on datasheet before considering a purchase. Here are the Simple Tests to confirm Wattage for 12v applications with PWM Solar charge controller before you order;   Test1:   Number of Cells, If it is 36 –  OK   Test2:   Ask Vmp. If it is a fixed value between 17v to 18v - OK (Because e ach cell is supposed to be     approximately 0.5V)   Test3:   Ask Imp. If it is fixed value between   to A for 20Watt Panel. - OK   Test4:   Multiply Vmp with Imp. If it comes to 10W – OK (i.e. 17V X Amp = 10 Watt or 18V X Amp = 10Watt)   Test5:   Please insist for the datasheet, and verify these figures
₹ 810
See product
India
Visit rajivihaan shop on http://stores..in/rajivihaan for other Solar, DC, or AC-DC Energy Efficient Products and Solutions   Please visit our website for more details: www.gaonsegaon/ecommerce or contact us at   It is important to verify the wattage of any panel based on datasheet before considering a purchase. Here are the Simple Tests to confirm Wattage for 12v applications with PWM Solar charge controller before you order;   Test1:    Number of Cells, If it is 36 –  OK   Test2:    Ask Vmp. If it is a fixed value between 17v to 18v -  OK  (Because  e ach cell is supposed to be approximately 0.5V)   Test3:    Ask Imp.  If it is fixed value between 5.55A to 5.88A for 100Watt Panel. - OK   Test4:    Multiply Vmp with Imp. If it comes to 100W  –  OK (i.e. 17V X 5.88Amp = 100 Watt or 18V X 5.55Amp = 100Watt)   Test5:    Please insist for the datasheet, and verify these figures
₹ 5.535
See product
India
Visit Rajivihaan shop on http://stores..in/rajivihaan for other Solar, DC, or AC-DC Energy Efficient Products and Solutions. Please click here for rajivihaan shop http://stores..in/rajivihaan   Please contact us at    or visit our website for more details:  www.gaonsegaon.com/ecommerce It is important to verify the wattage of any panel based on datasheet before considering a purchase. Here are the Simple Tests to confirm Wattage for 12v applications with PWM Solar charge controller before you order; Test1:   Number of Cells, If it is 36 –  OK Test2:   Ask Vmp. If it is a fixed value between 17v to 18v - OK (Because e ach cell is supposed to be     approximately 0.5V) Test3:   Ask Imp. If it is fixed value between   to A for 20Watt Panel. - OK Test4:   Multiply Vmp with Imp. If it comes to 20W – OK (i.e. 17V X Amp = 20 Watt or 18V X Amp = 20Watt) Test5:   Please insist for the datasheet, and verify these figures
₹ 1.610
See product
India
Visit rajivihaan shop on http://stores..in/rajivihaan for other Solar, DC, or AC-DC Energy Efficient Products and Solutions.   Please contact us at    or visit our website for more details:  www.gaonsegaon.com/ecommerce It is important to verify the wattage of any panel based on datasheet before considering a purchase. Here are the Simple Tests to confirm Wattage for 12v applications with PWM Solar charge controller before you order;   Test1:    Number of Cells, If it is 36 –  OK   Test2:    Ask Vmp. If it is a fixed value between 17v to 18v -  OK  (Because  e ach cell is supposed to be approximately 0.5V)   Test3:    Ask Imp.  If it is fixed value between 3.33 A to 3.53A for 60Watt Panel. - OK   Test4:    Multiply Vmp with Imp. If it comes to 60W  –  OK (i.e. 17V X 3.53Amp = 60 Watt or 18V X 3.33Amp = 60Watt)   Test5:    Please insist for the datasheet, and verify these figures
₹ 3.610
See product
India
Visit rajivihaan shop on http://stores..in/rajivihaan for other Solar, Dc, or AC-DC Energy Efficient Products and Solutions Please contact us at    or visit our website for more details:  www.gaonsegaon.com/ecommerce It is important to verify the wattage of any panel based on datasheet before considering a purchase. Here are the Simple Tests to confirm Wattage for 12v applications with PWM Solar charge controller before you order;   Test1:   Number of Cells, If it is 36 –  OK   Test2:   Ask Vmp. If it is a fixed value between 17v to 18v - OK (Because e ach cell is supposed to be     approximately 0.5V)   Test3:   Ask Imp. If it is fixed value between 2.22A to 2.35A for 40Watt Panel. - OK   Test4:   Multiply Vmp with Imp. If it comes to 40W – OK (i.e. 17V X 2.35Amp = 40 Watt or 18V X 2.22Amp = 40Watt)   Test5:   Please insist for the datasheet, and verify these figures
₹ 2.440
See product
India
Please visit rajivihaan shop on http://stores..in/rajivihaan  for other Solar, DC, or AC-DC Energy Efficient Products and Solutions, http://stores..in/rajivihaan Please contact us at    , or visit our website for more details: www.gaonsegaon.com/ecommerce    It is important to verify the wattage of any panel based on datasheet before considering a purchase. Here are the Simple Tests to confirm Wattage for 12v applications with PWM Solar charge controller before you order;   Test1:   Number of Cells, If it is 36 –  OK   Test2:   Ask Vmp. If it is a fixed value between 17v to 18v - OK (Because e ach cell is supposed to be     approximately 0.5V)   Test3:   Ask Imp. If it is fixed value between  to A for 30Watt Panel. - OK   Test4:   Multiply Vmp with Imp. If it comes to 30W – OK (i.e. 17V X Amp = 30 Watt or 18V X Amp = 30Watt)   Test5:   Please insist for the datasheet, and verify these figures
₹ 1.900
See product
India
Please visit rajivihaan shop on http://stores..in/rajivihaan  for other Solar, DC, or AC-DC Energy Efficient Products and Solutions, http://stores..in/rajivihaan Please contact us at    , or visit our website for more details: www.gaonsegaon.com/ecommerce    It is important to verify the wattage of any panel based on datasheet before considering a purchase. Here are the Simple Tests to confirm Wattage for 12v applications with PWM Solar charge controller before you order;   Test1:   Number of Cells, If it is 36 –  OK   Test2:   Ask Vmp. If it is a fixed value between 17v to 18v - OK (Because e ach cell is supposed to be     approximately 0.5V)   Test3:   Ask Imp. If it is fixed value between  to A for 10Watt Panel. - OK   Test4:   Multiply Vmp with Imp. If it comes to 10W – OK (i.e. 17V X Amp = 10 Watt or 18V X Amp = 10Watt)   Test5:   Please insist for the datasheet, and verify these figures
₹ 810
See product
India
Please visit rajivihaan shop on http://stores..in/rajivihaan  for other Solar, DC, or AC-DC Energy Efficient Products and Solutions, http://stores..in/rajivihaan Please contact us at    , or visit our website for more details: www.gaonsegaon.com/ecommerce    It is important to verify the wattage of any panel based on datasheet before considering a purchase. Here are the Simple Tests to confirm Wattage for 12v applications with PWM Solar charge controller before you order;   Test1:   Number of Cells, If it is 36 –  OK   Test2:   Ask Vmp. If it is a fixed value between 17v to 18v - OK (Because e ach cell is supposed to be     approximately 0.5V)   Test3:   Ask Imp. If it is fixed value between  to A for 50Watt Panel. - OK   Test4:   Multiply Vmp with Imp. If it comes to 30W – OK (i.e. 17V X Amp = 50 Watt or 18V X Amp = 50Watt)   Test5:   Please insist for the datasheet, and verify these figures
₹ 3.625
See product
India
Specifications 12v 5w solar panel Solar cells Electrical characteristics: Power (pm) in watts (normal): 5 Open circuit voltage in volts: Short circuit current in Amps: 0.30 Voltage at maximum power in volts: 17.0 Current at maximum power in Amps: 0.29 Maximum system voltage: 600v Physical parameters Solar cells per units.: 18 Length x width x thickness: mm: 295x185x22 inch: 11.4x7.3x0.8 Weight kg: 0.85 Mounting holes pitch (Y): mm: ) Mounting holes pitch (X): mm: ) Area sq M / Area sq fit: ) Junction box: IP 65 Other characteristics Type of cell: mono Front face: tempered glass (low Iron) Encapsulate: ethylene vinyl acetate Frame: anodized aluminium Junction box: weather proof nylon 6 Temp coefficient: voltage -v / K, current 4.4 ma / K, power -0.47% / K NOCT: 47 / -2 C Certifications: IEC / IEC / IEC ? TUV Safety Class II The standard range of modules is supplied without diodes. However, diodes can be provided on specific customer request at extra cost. All modules are supplied with shrivels hollow section frames. Warranty: up to 25 years limited extended warranty.
See product
India
Specifications 12v 100w solar panel Solar cells Electrical characteristics: Power (pm) in watts (normal): 100 Open circuit voltage in volts: 21.0 Short circuit current in Amps: 6.35 Voltage at maximum power in volts: 17.0 Current at maximum power in Amps: 5.88 Maximum system voltage: v Physical parameters Solar cells per units.: 36 Length x width x thickness: mm: x675x35 inch: 45.3x26.6x1.4 Weight kg: Mounting holes pitch (Y): mm: ) Mounting holes pitch (X): mm: ) Area sq M / Area sq fit: ) Junction box: IP 65 Other characteristics Type of cell: mono Front face: tempered glass (low Iron) Encapsulate: ethylene vinyl acetate Frame: anodized aluminium Junction box: weather proof nylon 6 Temp coefficient: voltage -v / K, current 4.4 ma / K, power -0.47% / K NOCT: 47 / -2 C Certifications: IEC / IEC / IEC ? TUV Safety Class II The standard range of modules is supplied without diodes. However, diodes can be provided on specific customer request at extra cost. All modules are supplied with shrivels hollow section frames. Warranty: up to 25 years limited extended warranty.
See product

Free Classified ads - buy and sell cheap items in India | CLASF - copyright ©2024 www.clasf.in.